Medium Capacity Flowmeters
Flomec medium capacity flowmeters find widespread application in industry to monitor & control liquid flow streams & allow precise dispensing of small to medium batch runs.
They also have extensive application in the distribution of fuels, fuel oils, lubrication, Alcohol, solvents & the blending of bio & ethanol fuels.
General Specifications
Flow range: Nominal sizes: Linearity: Repeatability: Temperature: Materials: Pulse outputs: |
15~450 liters/min 25~50mm (1”~2”) +/-0.5% of reading +/-0.03% repeatability -20~+120oC) 316 stainless or aluminum Reed switch & NPN open collector |
(Standard)
(*for full specifications see pages 10 & 11)
Standard Options
- Modular process connections
- LCD totalizer
- LCD flow rate totalizer
- LCD two stage batch controller
- Intrinsically Safe (I.S.) instrumental
- 4~20mA, scaled pulse & alarm output
- Integral mechanical totalizer / batch register
- Quadrature pulse output
Features
- High flow rangeability
- Modular construction aids installation
- Precise batching via “Hyperpulse” Technology
- Easy to read LCD or mechanical displays
- Choice of output suit most applications
- All metal rotors
|
![](/ekadharma/images/Content/JSG/BlinPulsemeter.gif)
Blin Pulse Meter
![](/ekadharma/images/Content/JSG/PulsemeterwithLCDregister.gif)
Pulse Meter with LCD Register
![](/ekadharma/images/Content/JSG/Mediumcapacitywithmechanicalmeter.gif)
Medium Capacity with Mechanical meter
|
Large Capacity Flowmeters
Flomec 3” and 4” large capacity flowmeters are highly competitive meter suited for receipt Verification, loading, un-loading & distribution Management at petroleum depot, mine sites, marine & Aviation facilities. Common transfer applications involve fuels, oils solvents, Alcohol along with the blending of bio & ethanol fuels. The meter are reatively compact & light Weights in construction, important benefits when used in mobile installations or within confined spaces.
General Specifications
Flow range: Nominal sizes: Linearity: Repeatability: Temperature: Materials: Pulse outputs: |
50~2500 liters/min (13~625 USGPM) 80 & 100mm (3” & 4”) +/-0.2% 15:1 turndown +/-0.03% repeatability -20~+120oC (-4~250oF) Aluminum or ductile iron Reed switch & NPN open collector |
(*for full specifications see pages 10 & 11)
Standard Options
- Modular process connections
- LCD totaliser
- LCD flow rate totaliser
- LCD two stage batch controller
- Intrinsically Safe (I.S.) instrumental
- 4~20mA, scaled pulse & alarm outputs
- Integral mechanical totaliser/batch register
- Quadrature pulse output
Features
- Modular process connections
- Compact & light Weights
- High flow capacity
- Modular construction aids installation
- Easy to read LCD or mechanical displays
- High resolution or Quadrature pulse outputs
- All metal rotors
|
![](/ekadharma/images/Content/JSG/LargeflowPulsemeter.gif)
Large flow Pulse meter
![](/ekadharma/images/Content/JSG/LargeflowwithLCD.gif)
Large flow with LCD
![](/ekadharma/images/Content/JSG/LargecapacitymetermechanicalregisterwithLCDregister.gif)
Large capacity meter mechanical register with LCD register
|
Custody Transfer Flowmeters
Medium & large capacity meter are supplied in the form of custody transfer assemblies incorporating peripheral devices to meet the requirements of industry and relevant approval bodies.
General Specifications
![](/ekadharma/images/Content/JSG/Mechanicalmeterwithwaferchecketc.gif)
Mechanical meter with wafer check valve, air eliminator, strainer & mechanical pre-set cut off valve
|
Model prefix :
|
0M025
|
0M040
|
OMO50
|
OMO50E
|
OMO80
|
OMO80E
|
OM100
|
OM100E
|
Nominal size (inches)
|
1”
|
1.5”
|
2”
|
2”
|
3”
|
3”
|
4”
|
4”
|
Materials
|
Aluminium body
|
Minimum delivery (liters)
|
5
|
10
|
20
|
35
|
50
|
50
|
200
|
150
|
Maximum flow(L/min)
|
150
|
250
|
450
|
580
|
750
|
1000
|
1500
|
2500
|
Output options
|
Reed Switch & NPN Hall, Quadrature Halls
|
Maximum pressure
|
10 bar (147 psig)
|
Mechanical Metering Assemblies
Meter 1” ~4” fitted with an angle adaptor will take various combinations of large mechanical register, presents register, printers & associated check & cut-off valves.
General Specifications
![](/ekadharma/images/Content/JSG/Mechanicalmeterwithwaferchecketc.gif)
Mechanical meter with wafer check valve, air eliminator, strainer & mechanical pre-set cut off valve
|
eter size (inches)
|
1”
|
1.5”
|
2”
|
3”
|
4”
|
Meter Materials
|
Aluminium body
|
Minimum delivery (liters)
|
5
|
10
|
20
|
50
|
200
|
Maximum flow (L/min)
|
150
|
250
|
450
|
1000
|
1500
|
Mechanical register
|
Reset & Preset with optional sprinter
|
Mechanical control
|
Two stage mechanical cut-off valve
|
Maximum pressure
|
10 bar (147psig)
|
Strainers & Air Eliminators
The modular design of the strainers & optional air eliminator head allow fitment as a stand alone or Close couple strainer only or as a multi-function strainer air eliminator check valve Assembly. Wafer back pressure check valves are fitted between the eliminator strainer (ES) and the flowmeter to aid in the extraction of air & prevent any possibility of reverse flow.
General Specifications
![](/ekadharma/images/Content/JSG/Aireliminatorstrainer.gif)
Air eliminator strainer
|
Model prefix
|
ES025
|
ES040
|
ES050
|
ES080
|
ES100
|
Nominal size (inches)
|
1”
|
1.5”
|
2”
|
3”
|
4”
|
Materials
|
Aluminium body, 316SS basket, viton seals
|
Strainer mesh sizes
|
100 mesh (150 micron)
|
Maximum pressure
|
10 bar (147psig)
|
Air release head
|
Dual port double reed valve
|
Venting capacity @ 10psig
|
154 CFM (4.36M 3/min@ 70kpa)
|
|